Yes. Hail dents metal roofing, the dent is usually permanent, and no panel on our price list or anyone else's is dent-proof. Two things matter beyond that. A dent in the flat of a panel is almost always cosmetic in the strict sense, and many Florida policies carry a cosmetic damage exclusion that will not pay to replace a roof that still keeps water out. And dent resistance is a real product variable driven by thickness, alloy and geometry, which a supplier controls and can put in a quote.
What actually decides how much a panel dents
Denting is a yield problem. A hailstone arrives with energy, it has to go somewhere, and if local stress exceeds the metal's yield strength the panel takes a permanent set. Five variables move the outcome:
- The energy of the stone, a function of size and fall speed, and the angle it strikes. A stone hitting a 5:12 slope obliquely delivers less normal force than one hitting flat.
- The thickness of the metal. Thicker resists better, which is the whole reason gauge is on the spec sheet.
- The yield strength of the metal. Our Grade 50 Galvalume steel is specified at 50 ksi minimum and our rib panel steel at 80 ksi minimum, while the 0.032 inch aluminum in our exposed fastener line is specified at 23 ksi minimum. Our own catalog figures, and not close together. Aluminum is the soft metal in the range whichever profile it is rolled into.
- Panel geometry. Striations and minor ribs rolled into the flat of a pan stiffen it and break up reflections. A wide, dead-flat pan shows a dent worst.
- What is behind the panel. One spanning open purlins has more room to deform than the same panel over a solid deck.
Note what is not on that list: the coating. PVDF and SMP are films measured in fractions of a mil and add no dent resistance, though hail can chip one at the point of impact, which matters within sight of salt water and very little inland.
What Florida hail actually is
Hailstones form when raindrops are carried upward by thunderstorm updrafts into very cold air and freeze. NOAA's National Severe Storms Laboratory is direct about the geography: although Florida has the most thunderstorms, Nebraska, Colorado and Wyoming usually have the most hailstorms, and the area where those three states meet averages seven to nine hail days a year. NSSL treats hail of one inch, quarter size, or larger as severe.
We are not going to publish a Florida hail frequency table or an average stone size for Jacksonville or Tampa, because we have not found a source we can stand behind. Florida gets hail, Florida is not the country's hail capital, and the design question here is not how often but what happens when. Wind is still the load that drives panel selection, covered in our hurricane season readiness guide.
The cosmetic damage exclusion, and what Florida law does and does not say
A cosmetic damage exclusion is a policy endorsement. It excludes damage that alters the appearance of the roof surface without impairing performance, which describes most hail dents in a metal pan.
We went and read the statutes. Florida Statutes 627.7011 and 627.701, the two provisions governing roof coverage and roof deductibles in a Florida homeowner's policy, say nothing about cosmetic damage in either direction. Florida neither requires the exclusion nor forbids it. It lives in your policy form, so the only reliable way to know whether you have one is to read your policy, or ask your agent in writing, before a storm rather than after. What the statutes do say is worth having in front of you:
- 627.701(10)(a)2. A roof deductible may not exceed the lesser of 2 percent of the Coverage A limit of the policy or 50 percent of the cost to replace the roof.
- 627.7011(5)(b). An insurer may not refuse to issue or refuse to renew a homeowner's policy insuring a residential structure with a roof that is less than 15 years old solely because of the age of the roof.
- 627.7011(5)(c). For a roof at least 15 years old, the insurer must allow a homeowner-paid inspection by an authorized inspector before requiring replacement, and may not refuse solely on roof age if that inspection shows 5 years or more of useful life remaining.
One more thing, because it gets oversold. There is no metal-specific credit anywhere on Florida's wind mitigation form, OIR-B1-1802 (Rev. 04/26), and no hail line on it either. Its roof covering credit is documentation-driven and applies identically to shingle, tile, metal, built-up and membrane. Do not buy a metal roof expecting a hail discount.
Gauge and substrate: the part a supplier controls
Here is what we actually run, which is the part of this we can do something about. A lower gauge number is thicker steel.
| Profile | Substrate and thickness | Dent resistance |
|---|---|---|
| SL100, SL150 snaplock | 24 ga steel | Best in our steel range |
| NS150 nailstrip | 24 ga steel | Best in our steel range |
| NS100 nailstrip | 24 ga or 26 ga steel | 24 ga better than 26 |
| M150 mechanical lock | 24 ga steel or 0.032 in aluminum | Steel version better |
| M100 mechanical lock | 0.032 in aluminum | Softer metal, chosen for salt |
| PBR / R-panel | 24 ga or 26 ga steel | 24 ga better than 26 |
| 5V crimp | 26 ga steel or 0.032 in aluminum | Middle of the range |
| Rib panel | 29 ga steel or 0.032 in aluminum | Thinnest steel we sell |
Going from 26 gauge to 24 gauge is the cheapest thing you can do about hail on a steel roof, and it buys wind performance and panel flatness at the same time. What that costs is in our piece on 24 versus 26 gauge for Florida wind loads.
Aluminum is not the hail answer. We put 0.032 inch aluminum on coastal jobs because it tolerates salt better than any steel we sell, but it is a softer metal with a much lower minimum yield, so an oceanfront aluminum roof deliberately trades dent resistance for corrosion resistance: the right trade within a few hundred feet of breaking surf, the wrong one three miles inland. Which side of that line you are on is the subject of our guide to aluminum versus steel by distance from the coast.
29 gauge rib panel is the thinnest steel in our catalog and the economical answer for a barn or pole building, and it will show hail sooner than anything else we sell. If the building is seen from the road, price 26 or 24 gauge PBR first.
What we will not do is quote you an impact resistance class. We do not publish one for our panels and will not imply one. If anyone hands you an impact class for a metal panel, ask to see the listing rather than the brochure.
What a dent does, and does not do, to the roof
On a standing seam roof, a dent in the flat of a pan does not disengage the seam, back out a clip or stop the panel shedding water. The roof is doing its job with a mark on it. That is genuinely different from a shingle roof, where hail bruises the mat and strips granules and the damage is a durability problem rather than an appearance one.
What is not merely cosmetic, and what an inspection should look for:
- A stone that split, cracked or punctured a panel, most likely on the thinnest gauges.
- Damage at a seam, clip, end lap or panel edge rather than in the field of the pan.
- Damage to flashings, valley metal, pipe boots, vents and curbs. These are lighter and more exposed than the panels, and they are where hail damage becomes a leak.
- On exposed fastener panels, 5V, rib and PBR, the gasketed washers under the fastener heads. Those washers are the water seal and the usual failure point on that panel family anyway, so a hail event is a good reason to walk them. See our piece on exposed versus concealed fastener panels.
- Coating chipped through to substrate. Inland that is a mark; within salt spray range it is a corrosion starting point.
One thing that is not damage at all: oil canning. Waviness visible in a pan under raking light is an aesthetic characteristic of light gauge metal, not a defect, and not grounds for a warranty claim. A hailstorm can make it more noticeable simply because you are finally up there looking. That distinction, and the rest of what is and is not covered, is in what a metal roof warranty actually covers.
What to do after a hailstorm
- Record the date and photograph the roof from the ground before anyone touches it.
- Have the roof walked by someone licensed. Look at seams, clips, flashings, pipe boots, valleys and fastener washers, not just pans.
- Read your policy for a cosmetic damage exclusion before you file.
- Do the deductible math. A separate roof deductible is capped by statute at the lesser of 2 percent of Coverage A or 50 percent of the cost to replace the roof.
- Do not accept an offer to cover, waive or discount your deductible from anyone. Florida Statute 489.147 prohibits offering a rebate, gift, gift card, cash, coupon, waiver of any insurance deductible, or any other thing of value in exchange for allowing a roof inspection or making a claim, and an unlicensed person doing it faces up to $10,000 for each violation.
- If panels need replacing, find the ERS Metals invoice and the coil lot or mill tag numbers. A replacement run has to match gauge, coating and color.
Speccing against hail without overpaying
Inland, on a house where appearance matters, 24 gauge steel standing seam is the sensible answer, and the same specification we would recommend for wind. If you want the marks to read less, ask whether the profile and finish you are quoting can be run with striations or a minor rib in the pan rather than dead flat, and confirm that before you order rather than assuming it. On a coastal house, take the aluminum and take the dent tradeoff knowingly. Nothing available is dent-proof, and we would rather say so up front than sell around it. Price the gauge options side by side through Instant Metal Quote, or send the project to our sales desk and we will lay out what the step from 26 to 24 gauge costs on your square footage.



